Flow Rate and Piping Size for a Solar Hot Water System
The flow rate and piping size are important considerations when designing and installing a solar hot water system.
The flow rate, measured in feet per second (fps), is generally recommended to be between 2 fps to 5 fps for a solar hot water system. If the flow rate is at the high end of this range, the heat exchanger will be more efficient and less scale will be created in the heat exchanger. A flow rate of greater than 2 fps is needed to entrain air through the piping. This is critical in a glycol system since a glycol solar water heating system will use some form of air elimination. In order to make effective use of the air elimination feature in the system the air needs to be carried to the device that will capture and release the air. If the flow rate is over 5 fps, excessive flow noise may be detected. When you get beyond 8 fps erosion corrosion may be produced inside the piping as well as noise. This internal corrosion of the pipes will ultimately lead to the system springing a leak.
Where solar collector manufacturers certify their product at a given flow rate solar collectors will operate well over a wide range of flows. If you understand the trade-offs between; 1) entraining air, 2) noisy/corrosive flow, and 3) pump energy you will be able to select the appropriate line size. The smaller the line the greater the pressure drop at a given flow rate. The smaller the line the lower the cost for the line set as well as the insulation. For most residential solar hot water systems, the inside diameter piping size should be between 1/2 inch to 1 inch. In addition to flow rate, piping size should also be determined by the length of piping needed, the type of pump used, the capacity of the collectors and whether the system is an open or closed loop. As a general rule the following is the maximum flow rate you should plan on for different size copper pipe.
| Pipe Diameter | Max Flow rate (gpm) |
| 3/8” | 2 |
| ½” | 3 |
| ¾” | 6 |
| 1” | 12 |
| 1 ¼” | 18 |
Generally, in designing a solar hot water system, using a larger pipe size will give you lower pressure drop. The lower pressure drop will result in less pump required to overcome the pipe resistance. This may (or may not) result in lower energy consumption for the pump. However, using the minimum pipe size will be the most cost effective.